4.9. WATER USE IN THE ELECTRIFIED AREA

All hoses used in the Electrified Area must be of high quality, with securely-screwed,
metal fittings.
All hoses and fittings must be inspected prior to use and only used if in good,
serviceable condition.
Any work near the OLE necessitating hosing with water which contains chemicals,
requires written approval from the EEM or their representative.
When hosing, special care must be taken to ensure that the water stream is not less
than three (3) metres from:
 Live OLE; nor
 the electrical equipment mounted on Electric Multiple Units (EMUs).