Civil – Non-Queensland Rail Underground Services in Queensland Rail Property (Previously known as CIVIL-SR-016) Version: 2.0 Updated: 04/12/2024
Civil – Non-Queensland Rail Underground Services in Queensland Rail Property (Version 2.0, Updated 04/12/2024)
Key Points:
- Purpose and Scope:
- Defines requirements for underground services within Queensland Rail reserve
- Applies to jointly owned services, externally owned services, and new third-party underground services
- Excludes Queensland Rail‘s optical fiber systems and owned services
- Main Requirements:
- Services must comply with Australian Standards and Codes of Practice
- Specific design and location requirements for different types of services
- Minimum depth requirements of 2m from top of formation
- Services must cross at 90° ±5° to track centerline
- Installation Methods:
- Approved methods include trenching, directional drilling, boring, pipe jacking and ramming
- High pressure water drilling is not permitted
- Each method has specific requirements and restrictions
- Service Types Covered:
- Power services
- Flammable and combustible fluids
- Non-flammable fluids
- Shared services with Queensland Rail
- Key Safety Requirements:
- Track monitoring during installation
- Rail traffic restrictions during works
- Construction requirements and specifications
- Maintenance and inspection protocols
- Documentation Requirements:
- As-constructed drawings
- Geotechnical reports
- Work method statements
- Required authorizations and permits
The document provides comprehensive technical specifications and safety requirements for installing and maintaining underground services in Queensland Rail property, with a focus on protecting rail infrastructure and ensuring safe operations.