Secondary tracks are lower-speed routes serving branch lines, local traffic, and industrial connections.
Basic Parameters
| Parameter | Standard | Minimum | Maximum |
|---|---|---|---|
| Track Gauge | 1435mm | 1432mm | 1440mm |
| Rail Profile | 54E1/49E1 | 46E1 | 54E1 |
| Sleeper Spacing | 650mm | 600mm | 700mm |
| Ballast Depth | 250mm | 200mm | 300mm |
| Track Centers | 3.8m | 3.5m | 4.0m |
Speed Classifications
| Class | Passenger | Freight | Usage |
|---|---|---|---|
| Class 3 | 80-120 km/h | 60-80 km/h | Regular |
| Class 4 | 60-80 km/h | 40-60 km/h | Limited |
| Class 5 | 40-60 km/h | 30-40 km/h | Local |
| Class 6 | <40 km/h | <30 km/h | Industrial |
| Yard | <25 km/h | <25 km/h | Shunting |
Geometric Standards
| Parameter | Standard | Minimum | Maximum |
|---|---|---|---|
| Curve Radius | 400m | 200m | 800m |
| Gradient | 2.0% | 0% | 3.5% |
| Cant | 120mm | 0mm | 150mm |
| Transition Length | 200m | 100m | 300m |
| Vertical Curve | 2000m | 1000m | 5000m |
Maintenance Tolerances
| Parameter | New | Warning | Limit |
|---|---|---|---|
| Gauge | +2/-1mm | +4/-2mm | +6/-3mm |
| Alignment | ±3mm | ±8mm | ±12mm |
| Cross Level | ±3mm | ±8mm | ±12mm |
| Twist (3m) | 1:500 | 1:400 | 1:300 |
| Rail Wear | 0mm | 12mm | 15mm |
Infrastructure Requirements
| Component | Specification | Tolerance |
|---|---|---|
| Formation | E₂ ≥ 45MPa | ±5MPa |
| Sub-ballast | 100mm | +30/-0mm |
| Ballast | 250mm | +50/-0mm |
| Drainage | 1:30 slope | ±1:50 |
| Shoulder Width | 400mm | +100/-0mm |
Inspection Frequency
| Element | Visual | Measured | Detailed |
|---|---|---|---|
| Track | Weekly | Monthly | Annual |
| Switches | Daily | Weekly | Quarterly |
| Structures | Monthly | Quarterly | Annual |
| Drainage | Monthly | Seasonal | Annual |
| Vegetation | Monthly | Seasonal | Annual |
Loading Standards
| Type | Axle Load | Speed |
|---|---|---|
| Freight | 22.5t | 60 km/h |
| Passenger | 18.0t | 80 km/h |
| Light Rail | 16.0t | 100 km/h |
| Special | 25.0t | 40 km/h |
| Maintenance | 20.0t | 50 km/h |
Switch Types
| Type | Length | Speed |
|---|---|---|
| 1:8 | 16.5m | 40 km/h |
| 1:9 | 18.5m | 50 km/h |
| 1:10 | 22.0m | 60 km/h |
| 1:12 | 27.5m | 80 km/h |
| Trap | 12.0m | 25 km/h |
Signaling Systems
| Type | Block Length | Control |
|---|---|---|
| Color Light | 800m | Local |
| Mechanical | 600m | Manual |
| Token Block | Variable | Staff |
| Radio | Variable | Central |
| Basic | Visual | Rules |
Track Components
| Component | Standard | Life Expectancy |
|---|---|---|
| Rails | 54E1/49E1 | 20-25 years |
| Sleepers | Concrete/Wood | 30/15 years |
| Ballast | 31.5-50mm | 15-20 years |
| Fasteners | Elastic | 10-15 years |
| Joints | 6m/18m | 5-8 years |
Maintenance Schedule
| Activity | Frequency | Tolerance |
|---|---|---|
| Inspection | Weekly | +3 days |
| Tamping | Annual | ±2 months |
| Grinding | 3 years | ±6 months |
| Ballast Clean | 10 years | ±1 year |
| Renewal | 25-30 years | ±5 years |
Environmental Controls
| Factor | Standard | Action |
|---|---|---|
| Noise | 75dB(A) | Monitoring |
| Vibration | 75VdB | Check |
| Drainage | 100mm/h | Clear |
| Vegetation | 3m clearance | Cut |
| Pollution | Basic | Control |
Operational Parameters
| Aspect | Requirement | Notes |
|---|---|---|
| Headway | 15-30 min | Peak |
| Capacity | 6-8 tph | Mixed |
| Dwell Time | 1-2 min | Stations |
| Recovery | 8% | Timetable |
| Reliability | 90% | Target |